Instruments |
|
| |
Chlorine Residual Analyzer |
 |
|
|
|
|
| |
Insertion Type Electromagnetic Flowmeter |
|
 
|
When low costs and installation speed are pre-eminent requirements, insertion flow meter represents a good compromise between cost and performance.
Like all magnetic meters it can be used for measuring the flow rate of all liquids that have electrical conductivity (a few µS/cm).
It is composed of a probe that is installed in such a way that its axis forms a 90° angle with the axis of the main pipe.
The insertion electromagnetic sensors are built in three models. It can be supplied in compact version only with MC 106 A, MC 306, MC308 (only with housing in ABS)converters.
|
|
Technical Data:
PN [Bar] 16
Max. Temp. 130 °C
Size [mm] 3<1000 4< 1600 5< 2000
|
Technical Data
PN [Bar] 10
Max. Temp. 60 °C
Size [mm] AA < 250 mm
|
| |
Flanged Type Electomagnetic Flowmeter |
|
 
|
MUT 2200 EL and MUT 2500 EL sensors represent the state of the art of production for water cycle and process applications. The new structure for the generation of the magnetic field, the innovative route of the signal generated by the electrodes, provide a sensor with an extremely wide measurement range:EL= Extended Linearity.
|
|
MUT 2200 EL-Technical Data
DN: from 25 up to 400 mm
PN: Standard 16 bar (others on request up to 64 bar)
Flanges: standard UNI 2223, DIN 2501, BS 4504 on request ANSI 150/300, AWWA, KS
|
MUT 2500 EL-Technical Data
DN: from 450 up to 2000 mm
PN: Standard 16 bar others on request up to 64 bar
Flanges: standard UNI 2223, DIN 2501, BS 4504
on request ANSI 150/300, AWWA, KS
|
| |
Converter |
|



|
MC308 converter is available in three different enclosures. ABS enclosure with protection degree IP 67; cast aluminium enclosure with protection degree IP 67; die cast aluminium cylindrical enclosure with protection degree IP 68.
Cylindrical aluminium enclosure may be rotated by 90° around the junction box axis without opening it.
The MC 308 can be delivered either in compact or in separate version. In separate version the maximum distance between sensor and MC308 depends on conductivity of the liquid and the maximum is 100 m.
It has on an LCD display and the keyboard.
|
|
Technical Data
- simple programming process (MENU based)
- a built-in batching option
- a built-in "low consumption" operating mode
- empty pipe control by two options: conductivity and optical
- two lines sixteen characters display
- 4(0)-20 mA output (insulated)
- two ON/OFF outputs (pulse, alarm..)
- input for totalizers remote reset or batching start/stop
- RS 485 interface (insulated)
- power supply 90...264 Vac; (24 Vac/dc on request)
- forward and reverse flowrate measurement
- max and min flowrate alarm
- plug connection for TRM 100 programmer
- many languages for the messages are available (on request)
- custom password
- housing and keyboard sealing
|
|
| |
3.5 m Ultrasonic Level Sensor |
 |
|
|
|
|
| |
8m Ultrasonic Level Sensor |
 |
|
|
|
|
|
|
|